Table for cable size CB.S6004&6346

  • Circuit = 240 volt supply

  • Watts  = volts × amps

 

  • Amps  = watts/volts

  • Voltage loss = voltage drop × length of cable × amps

         

  • Check does it comply with the 2.5% rule:

                                                     


Lighting Circuit


Power circuit

               


           

Circuit 1

Cooker oven = 4350 watts

 

Amps = watts/volts

Using a 240 volt supply: Amps =4350/240

Join now!

                                       Amps = 18.125

Voltage loss = voltage drop × length of cable × amps

Voltage loss = 0.011 × 30 × 18.125  =  5.98volts

Check does it comply with the 2.5% rule:

                                                     

5.98/240 × 100/1= 2.49%  (under 2.5%)

Table for cable size CB.S6004&6346(circuit 1)

...